SECTION 5 SERVICE TECH. INFORMATION
I I
5A. TROU BLES HOOTI NG
Keep this manual with your water softener. If repairs are needed, the service technician must have the informa-
tion on the following 8 pages. For telephone assistance, call toll free, 1-800-426-9345.
WIRING SCHEMATIC
Transformer
Turbine
Sensor
BACK OF TIMER I
_I
/ [ 24VAC
grn
o- ._.NC Position
brn Switch
°NO
f
SearsWaterLine
for CustomerAssistance
1-800-426-9345
SALT SIGNAL
LEV[L LEV[L
0Ec.A00.0..0..
t°g .oL2_.Ec.A.GE.0w
Deluxe Demand Water Softener
with DualSegmentElectronicDisplay
)
ALWAYS MAKE THESE INITIAL CHECKS FIRST
1. Does the time display show the correct time of day?
°
°
°
°
--If display is blank, check power source to the soft-
ener.
--If time is flashing, power was off" f_)r over 24 hours. The
softener resumes normal operation but regenerations
occur at the wrong time.
--If an error code (Example: Err3) shows in the face plate
display, go to ALTOMATIC ELECTRONIC DIAGNOS-
TICS.
Plumbing bypass valve(s) must be in Full Service
position.
The inlet and outlet pipes must connect to the softener
inlet and outlet respectively.
Is the transfk)rmer plugged into a "live", grounded wall
outlet, and the power cable fastened securely?
The valve drain hose must be flee of kinks and sharp
bends, and not elevated over 8 ft. above the floor.
REMOVE THE TOP COVER AND SALT TANK COVER
6. Is there salt in the storage tank?
"7. Is the brine tubing connected? (See water flow
diagrams).
8. Is the brine valve float set right? (See page 23).
°
Press the SELECT button 2 times to display the hardness
setting. Be sure it is the con'ect setting for the
household's water supply. (Make a hardness test of the
raw water and compare with the hardness setting. Also
test a soft water sample to verify if a problem exists.)
Press the SELECT button twice more to return to
present time in the display.
If you do not find the problem after making initial checks,
do the MA2VUAL INITIATED ELECTRONIC DIAGNOSTICS,
and the MANIYALADVANCE REGENERATION CHECK.