Kenmore 505 Water Heater User Manual


 
Flue Installation for the 305 and 505 Models
Horizontal Termination without using the Condensate Collector
* The condensate collector must be used _..4"
in horizontal terminations if a vertical rise II I1_
in the vent system exceeds 5ft
,,thecondensateco,,ector,snotused,thedra,np,pemust ° 11IH
be capped to prevent exhaust gases and condensate from t _ !!_ _ 'P=_
enteringthebuilding.Thecapissuppliedontheappliance./ f H L-----_II _1 IIF])
\ 5 feet (1.52 m)I I Regions of cotd cti.matewill create
/ III II _ I I I moreconaensa_einmeven_system.
/ INK ) I I I Thecondensatecollectorshouldbe
q==J- _' I I usedincoldclimates.
_' _1 I If more than one elbow isused inthe
H H vertical section the condensate
L_ _-U .j L _ co,lectormustbeused.
Horizontal Termination using
the Condensate Collector
Condensate
Trap
t 3 !n.(75 mm)
minimum
Vertical Termination
(condensate collector must be used in all installations)
3 in (75 mm)
minimum
3 in (75 mm)
minimum
Condensate Collector
Bracket
To adjust the condensate collector position or to
replace the female vent top with a male vent top:
1. Loosen the 4 screws at the rear bracket
2. Slide the bracket away from the female vent top.
3. Remove the 4 screws attaching the female vent
top to the water heater.
4. Lift up the female vent top and reposition as
desired (or replace with a male vent top).
5. Install the 4 screws at the vent top and tighten the
4 screws at the bracket.
1o_1 Ill
Securing Screw
_J
Secure the first vent component to the water heater
with one self-tapping screw at the hole located above
the condensate collector.
Figure 10
305 & 505 Indoor Manual 21