Kenmore 153.337414 Water Heater User Manual


 
Safety Precautions
I _WARNING .
Improper installation, adjustment, altev_tlon, service or
maintenance can cause DEATH, SERIOUS BODILY
INJURY, OR PROPERTY DAMAGE. Refer to this menu-
at for assistance or consult your local Sears Service
Center for further information.
AWARNING
WATER HEATERS EQUIPPED FOR ONE TYPE GAS
ONLY: This water heater is equipped for one type gas
only. Check the model rating plate near the gascontrol
valve for the correct gas, DO NOT USE THIS WATER
HEATER WITH ANY GAS OTHER THAN THE ONE
SHOWN ON THE MODEL RATING PLATE. Failure to
usethe correct gascan causeproblemswhichcan result in
DEATH, SERIOUS BODILY INJURY, OR PROPERTY
DAMAGE. If you have any questions or doubts consult
yourgassupplieror localutility.
AW_!_tRNING
INSTALLATIONS IN AREAS WHERE FLAMMABLE LIQ-
UIDS (VAPORS) ARE LIKELY TO BE PRESENT OR
STORED (GARAGES, STORAGE, AND UTILITY AREAS,
ETC), Flammable liquids (such as gasoline, solvents,
propane(LP) or butane, eta), all of whichemit flammable
vapors, may be improperly stored or used in suchareas.
The gaswater heater pilot light or main burner can ignite
such vapors. The resulting flashback and fire can cause
death or serious bums to anyonein the area, as well as
property damage.
If installation in suchareas isyour only option, then the
installationmust be accomplishedin a way that the pilot
flame and main burner flame are elevated from the floor
at least 18 inches.While this may reduce the chancesof
flammable vaporsfrom a floor spillbeing Ignited, gasoline
and other flammable substancesshouldnever besto_l or
used in the same room or area contain ng a gas water
heater or other openflame or spark producingappliance.
NOTE: Flammable vapors may be drawn by air currents
from other areasofthe structure to the appliance.
AWARNING
If this water heater will be used in beauty shops,barber
shops,cleaning,establishments, or self-service laundries
with dry cleaning equipment, it is imperative that the
water heater or water heaters be installed so that com-
bustlon and ventilation air be taken from outside these
areas. Refer to the "Facts to Consider About the
Location" section of this manual and also the latest edi-
tion of the National Fuel Gas Code, ANSI Z223.1, also
referred to as NFPA 54 for specificsprovided €oncemnin
air required.
AWARNING
A fire can start if combus_ble mate.rialssuchas clothing,I
I cleaningmaterials,or flammable liqmdsare placedagainstI
I OrnexttOthe water h_=ter" I
A WARNING
At the time of manufacture this water heater was previd-/
ed with a combination temperature-pressures relief valve
certified by a nationally recognized testing laboratory
that maintains periodic inspectionof production of listed
equipment or materials, as meeting the requirements
for Relief Valvesand Automatic Gas Shutoff Devicesfor
Hot Water Supply Systems, and the latest edition of
ANSI Z21.22 and the code requirements of ASME. If
replaced, the valve must meet the requirements of local
codes,but not lessthan a combination temperature and
pressure relief valve certified as meeting the require-
ments for Relief Valves and Automatic Gas Shutoff
Devicesfor Hot Water Supply Systems,ANSI Z21.22 by
a nationally recognized testing laboratory that maintains
periodic inspectionof production of listed equipment or
materials.
The valvemust be marked with a maximum set pressure
not to exceed the marked hydrostatic working pressure
of the water heater (150 Ibs./sq. in.) and a discharge
capacity not lessthan the water heater input rate as
shown on the model rating plate. (Electric heaters.
watts divided by 1000x 3415 equal BTU/Hr. rate.)
Your local jurisdictional authority, while mandating the
use of a temperature-pressure relief valve complying
with ANSI Z21.22 and ASME, may require a valve model
different from the one fumnishedwith the water heater.
Compliance with such local requirements must be satis-
fied bythe installer or end user of the water heater with
a locally prescribed temperature-pressure relief valve
installedin the designatedopening in the water heater in
)laceof the factory furnished valve.
For safe operation of the water heater, the relief valve
must not be removed from it's designated opening or
plugged.
The temperature-pressure relief valve must be installed
directly into the fitting of the water heater designated
for the relief valve. Positionthe valvedownward and pro-
vide tubing sothat any dischargewill ex'_ only within 6
inches above, or at any distance below the structural
floor. Be certain that no contact is made with any live
electrical part. The dischargeopening must not be
blocked or reduced in size under any circumstances.
Excessivelength, over 30 feet, or use of more than four
elbows can cause restrlctionand reduce the discharge
capacity ofthe valve.
No valve or other obstruction is to be placed between
the relief valve and the tank. Do not connect tubing
directly to dischargedrain unlessa 6" air gap isprovided.
To prevent bodilyinlury, hazardto life, or property dam-
age, the relief valve must be allowed to dischargewater
in quantities should circumstances demand. If the dis-
charge pipe isnot connected to a drain or other suitable
means, the water flow may causeproperty damage.
The DischargePipe:
Must not be smaller in sizethan the outlet pipe size of
the valve, or have any reducing couplings or other
restrictions.
Must not be pluggedor blocked.
Must be of material listedfor hot water distribution.
Must be installed so as to allow complete drainage of
both the temperature-pressure rehef valve, and the
dischargepipe.
Must terminate at an adequate drain.
Must not have any valve between the relief valve and
tank.
2