Customer Responsibilities
Thank You for purchasing a Sears water heater.
Properly installed and maintained, it should give you years of
trouble free service. If you should decide that you want the new
water heater professionally installed by Sears call the local Sears
Service Cemer or any Sears store. They will arrange for prompt,
quality installation by Sears authorized contractors.
Abbreviations Found In This Instruction Manual
C.S.A.. - Canadian Standards Association
A.N.S.I. - American National Standards Institute
N.EP.A. - National Fire Protection Association
AWARNING
This gas-fired water heater is design certified by CSA
INTERNATIONAL underAmerican National Standard/CSA
Standardfor Gas Water Heaters ANS Z2 .10. --CSA 4.
(latest edition). The installation must conform with this
manual, Local Codes and with the latest edition of the
National FuelGasCode,ANSI Z223.1.
Thispublicationisavailablefrom your localgovernment or
public library, gas company, or by writing NFPA,
Batterymarch Park, Quincy,MA 02269.
Read the "Safety Precautions" section, pages 2 through 4 of
this manual first and then the entire manual carefully. If you
don't follow the safety rules, the water heater will not operate
properly. It could cause DEATH, SERIOUS BODILY
INJURY AND/OR PROPERTY DAMAGE.
This manual contains instructions for the installation, opera-
tion, and maintenance of the gas-fired water heater. It also
contains warnings through out the manual that you must read
and be aware of. All warnings and all instructions areessential
to the proper operation of the water heater and your safety.
Since we cannot put everything on the first few pages, READ
THE ENTIRE MANUAL BEFORE ATTEMPTING TO
INSTALLOR OPERATE THE WATER HEATER.
The installation must conform with the instructions in this
manual; gas company rules; and Local Codes, or in the
absence of Local Codes, with the latestedition of the National
Fuel Gas code, ANSI Z223.1, also referred to as NFPA 54.
This publication is available from your local government or
public library or gas company or by writing NFPA,
Batterymarch Park,Quincy, MA 02269.
If after reading this manual you have any questions or do not
understand any portion of the instructions, call the Sears
Service Center.
Carefully plan the place where you are going to put the water
heater. Correct combustion, vent action, ana vent pipe instal-
lation are very important in preventing death from possible
carbon monoxide poisoning and fires.
Examine the location to ensurethe water heater complies with
the "Facts to Consider About the Location" section in this
manual.
For California installation this water heater must be braced,
anchored, or strapped to avoid falling or moving during an
earthquake. See instructions for correct installation proce-
dures. Instructions may be obtained from your local dealer,
wholesaler, public utilities or California Office of the State
Architect, 400 P Street, Sacramento, CA 95814.
Complies with SCAQMD rule #1121 and districts having
equivalent NOx requirements.
Product Specifications
MODEL
NUMBER
153,332111
153.332161
153.332319
153.332363
153.332419
153.332463
153.332563
TANK
CAPACITY
IN GALLONS
39
39
30
30
40
40
50
TYPE
OF
GAS
NATURAL
NATURAL
NATURAL
NATURAL
NATURAL
NATURAL
NATURAL
B.T.U.
RATE
33,000
33,000
30,000
30,000
32,000
32,000
32,000
RECOVERY RATE
GALS. PER HOUR
@90°F RISE
34.0
34.0
31.0
31.0
33.0
33.0
33.0
MINIMUM
VENT
PIPE
y'
3"
3"
3"
3"
3"
3"
DIMENSIONS IN INCHES
HEIGHT TO
DIAMETER JACKETTOP
24" 36_"
24" 36_"
16" 56"
16" 56"
18" 56_"
18" 56_"
20" 56_"
6