Kenmore 153.330451 Water Heater User Manual


 
Installation Instructions (cont'd)
Installation Checklist
BEFORE LIGHTING THE PILOT:
Check the gas lines for leaks.
a. Use a soapy water solution. DO NOT test for gas leaks
usin_a match or open flame.
b. Brusn the soapy water solution on all gas pipes, joints and
fittings.
c. Check for bubbling soap. This means you have a leak.
Turn "OFF" gas andmake the necessary repairs.
d. Recheck for leaks.
e. Rinse offsoapy solution and wipe dry.
Is the new temperature-pressure relief valve properly installed
and piped to an adequate drain? See "Temperature-Pressure
Relief Valve" section.
Are the cold and hot water lines connected to the water
heater correctly? See "Water Piping" instructions in the
"Installation Instructions" section.
Is the water heater,completely filled with water? See "Filling"
instructions in the Installation Instructions".
Will a water leak damage anything? See the "Facts to
Consider About the Location" section.
Is there proper clearance between the water heater and any-
thing that might catch fire? See the Facts to Consider About
the Location" section.
Do you have adequate ventilation so that the water heater
will operate properly? See "Combustion Air and Ventilation"
in the "Facts to Consider About the Location" section.
!s the draft hood vent piping properly secured? See "Venting"
mstrucuons in the "Installation Instruct'ons' section.
Is there proper clearance between the vent pipe and anything
that might catch on fire? See "Venting" instructions in the
"Installation Instructions" section.
Is the vent pipe properly sloped and does the vent terminate
outdoors? See "Venting" instructions in the "Installation
Instructions section.
Do you need to call your gas company to check the gas pipe
and its hookup?
CHECK FOR LEAKS
Be sure to check all your gas pipes for leaks before lighting your
water heater. Use a soapy water solution, not a match or open
flame. Check the factory gas fittings after pilot is lit and gas con-
trol knob is still in "PILOT" position. Then, check the fittings
when the main burner is turned "ON". Use a soapy water solu-
tion for this, too.
VENT PIPE TO
OUTDOORS
OR CHIMNEY
HOT COLD
UNION SHUTOFF VALVE
HOT- •COLD
GAS SUPPLY
DRAFT
HOOD
PRESSURE
RELIEF VALVE
DISCHARGE PIPE
(Do not cap or plug)
SHUTOFF C_
VALVE
DRIP LETGEE'_ mmn_ _ _-_
(SEDIMENT _ R _ DRAIN VALVE
TRAP) J_ _ '(under cover)
P,PECAPleg
,,NCHA,RGAP
OOR DRAIN
._S _1_1O
I I I
15o I . I w 1 wc
MODEL RATING PLATE
16