Jotul GF 400 DV Electric Heater User Manual


 
7
Stove and Vent Clearance
Requirements
Minimum Clearances from the Stove
to Combustibles:
See figs. 2-4.
Rear: 2” (51 mm)
Ceiling: 32 1/4” (819 mm)
Corner: 2” (51 mm)
Sides: 3” (76 mm)
Minimum Clearances from the Vent Pipe to
Combustibles:
Horizontal Run:
Off the top of the pipe 2” (51 mm)
Off the sides and bottom 1” (25 mm)
Vertical Run:
All sides 1” (25 mm)
3”
(76 mm)
Figure 3. Parallel Installation Clearances.
Figure 4. Corner Clearances.
Figure 2. Mantel and Trim Clearance specifications.
Back of bottom plate is flush with the fireplace face.
Subtract 2 1/4” with Short Legs.
2”
(51 mm)
To Rear Wall
2”
51 mm
2”
51 mm
3”
(76 mm)
40 1/4
102.2 cm
43 3/4
111 cm
12.5
10.25
8
5.75
3.5
2 (5.1cm)
Max. Mantel Depth
Min. Mantel Depth
Minimum Ceiling or Alcove Height
61
155 cm
42 5/8
108.3 cm
46 1/2
118 cm
45 1/8
114.6 cm
28 1/2
72.3 cm
Max. Top Trim Depth = 1
Alcove Installation
Maximum Alcove Depth: 24” (61 cm)
Minimum Alcove Width: 31 3/4” (80.6 cm)
Minimum Ceiling Height: 61” (155 cm)
With Short Legs (6”) : 59” (150 cm)
Alcove dimensions result from test
configurations, not stove clearance
specifications.