Jotul GF 400 DV Electric Heater User Manual


 
11
HORIZONTAL RUN
35 Ft.
(10.67 m)
30 Ft.
(9.14 m)
25 Ft.
(7.62 m)
20 Ft.
(6.10 m)
15 Ft.
(4.57 m)
5 Ft.
(1.52 m)
Min. Rise
2 Ft.
(.60 m)
10 Ft.
(3.05 m)
5 Ft.
(1.52 m)
VERTICAL RUN
15 Ft.
(4.57 m)
20 Ft.
(6.09 m)
27 Ft.
(8.22m)
12 Ft.
(3.65 m)
8 Ft.
(2.43 m)
A
B
OPEN AIR INLET
RESTRICTOR
D
B
Up to four 45° or
two 90° elbows
permitted in
addition to the
starter elbow.
2 Ft.
(16 cm)
VERTICAL RUN
Minimum
Vertical
Termination
8 Ft.
(2.43 m)
35 Ft.
(10.67 m)
25 Ft.
(7.62 m)
2 Ft.
(16 cm)
VERTICAL RUN
Minimum
Vertical
Termination
8 Ft.
(2.43 m)
C
D
Figure 11. Coaxial Vent Termination Window / LP Figure 12 . Colinear Termination / LP
Vent Termination Zones - Propane
VENTING MUST
TERMINATE (END)
WITHIN THE SHADED
AREA.
Adjust the Exhaust
Restrictor to position C
for a straight vertical
colinear termination.
Adjust the Exhaust
Restrictor to position D
for a vertical colinear
termination with
maximum 2 ft. offset.
VENTING MUST TERMINATE (END) WITHIN ONE OF THE DESIG-
NATED AREAS. ZONE “A” IS FOR VERTICAL TEMINATIONS ONLY.
SET STOVE EXHAUST RESTRICTOR TO THE POSITION THAT CORRE-
SPONDS TO THE VENT TERMINATION AREA IN THE DIAGRAM
ABOVE.
OPEN AIR INLET RESTRICTOR FOR TERMINATIONS 5 FT AND
UNDER. SEE FIG. 6, PAGE 9.
ALWAYS MAINTAIN THE PROPER CLEARANCES TO COMBUSTIBLES.
The circled letter designations in the vent diagram correspond
to the Exhaust Restrictor Setting on the stove. First, determine
which vent termination zone is appropriate for your installa-
tion and fuel type, then adjust the stove restrictor plate to the
corresponding position as shown in Figure 7, page 9.
Vertical
Termination for
COLINEAR VENT
Horizontal and Vertical
Terminations for COAXIAL VENT