12
Jøtul F 100 USA Clearance Chart
All clearances established with included stove rear heat shield installed.
Stove Unprotected Surface Protected Surface
Clearances Installation per NFPA211 or CAN/CSA -B365-M93
Side Rear Corner* Side Rear Corner*
ABJ C D K
Single-wall Connector 15” 11” 10” 10” 5” 7”
381 mm 280 mm 254 mm 254 mm 127 mm 178 mm
Single-wall Connector EFLGHM
with Connector Shields 17” 8” 10” 10” 5” 7”
or Double-wall Connector* 432 mm 203 mm 254 mm 254 mm 127 mm 178 mm
Chimney Connector Unprotected Surface Protected Surface
Vertical Installation per NFPA211 or CAN/CSA-B365-M93
Single-wall Connector 11” (280 mm) 6” (153 mm)
Single-wall Connector
with Connector Shields 8” (203 mm) 5” (127 mm)
or Double-wall Connector*
Chimney Connector Unprotected Surface Protected Surface
Horizontal Installation per NFPA211 or CAN/CSA-B365-M93
Single-wall Connector 18” (457 mm) 12” (305 mm)
Double-wall Connector* Manufacturer’s Listing Manufacturer’s Listing
* Double Wall Connector must be installed with Flue Collar Heat Shield Kit 154996.
Mantel and Trim Clearances
Top and Side Trim is 1" thick or less
Maximum Mantel depth 12"
Unprotected Surfaces Protected Surfaces
A. Mantel 22” (560 mm) 9” (230 mm)
B: Top Trim 17” (430 mm) 8” (200 mm)
C: Side Trim 14” (355 mm) 7” (430 mm)
USA/CANADA
Figure 12