ITT BPHV Water Pump User Manual


 
37
TECHNICAL DATA – PUMP HYDRAULICS / MOTOR SIZING
1SV 3500 RPM
Number of
Maximum Motor HP for use Motor HP for use Shutoff Shutoff
Stages
HP With 1.15 SF With Hydrovar TDH TDH MAWP Motor Rotation
Draw Motor (1.0 SF) (Feet) (Bar)
22 6.7 7.5 7.5 1100 32.8
20 6.1 7.5 7.5 1005 30.0 580 PSI (40 Bar) CCW
18 5.4 5 7.5 905 27.0
16 4.8 5 5 795 23.7
15 4.6 5 5 742 22.2
13 4 5 5 642 19.2
11 3.4 3 5 550 16.4
9 2.7 3 3 445 13.3
8 2.4 3 3 398 11.9 362 PSI (25 Bar) CW
7 2 2 2 350 10.4
6 1.8 2 2 300 9.0
5 1.5 1.5 1.5 250 7.5
4 1.1 1 1.5 200 6.0
3 0.9 3/4 1 142 4.2
2 0.6 1/2 3/4 100 3.0
2SV 3500 RPM
Number of
Maximum Motor HP for use Motor HP for use Shutoff Shutoff
Stages
HP With 1.15 SF With Hydrovar TDH TDH MAWP Motor Rotation
Draw Motor (1.0 SF) (Feet) (Bar)
22 7.7 7.5 NA 950 28.4
20 6.8 7.5 7.5 860 25.7 580 PSI (40 Bar) CCW
18 6.2 7.5 7.5 760 22.7
16 5.3 5 7.5 726 21.7
15 4.9 5 5 680 20.3
13 4.6 5 5 595 17.8
11 4 5 5 500 14.9
9 3.3 3 5 407 12.2
8 2.9 3 3 360 10.7
7 2.4 3 3 315 9.4 362 PSI (25 Bar) CW
6 2.1 2 3 270 8.1
5 1.8 2 2 222 6.6
4 1.5 1.5 1.5 175 5.2
3 1.1 1 1.5 137 4.1
2 0.7 3/4 1 92 2.7
3SV 3500 RPM
Number of
Maximum Motor HP for use Motor HP for use Shutoff Shutoff
Stages
HP With 1.15 SF With Hydrovar TDH TDH MAWP Motor Rotation
Draw Motor (1.0 SF) (Feet) (Bar)
16 17.6 20 20 1010 30.2
580 PSI (40 Bar) CCW
14 15 15 15 894 26.7
13 14 15 15 830 24.8
12 12.8 15 15 760 22.7
11 11.5 10 15 700 20.9
10 10.7 10 15 640 19.1
9 9.7 10 10 575 17.2
8 8.5 7.5 10 505 15.1
362 PSI (25 Bar) CW
7 7.5 7.5 7.5 450 13.4
6 6.5 7.5 7.5 380 11.3
5 5.4 5 7.5 320 9.6
4 4.3 5 5 250 7.5
3 3.3 3 5 190 5.7
2 2.2 2 3 128 3.8