ITT BPHV Water Pump User Manual


 
17
3500 RPM, 60 Hz
HP Phase Enclosure
Nameplate NEMA Goulds
FLA SFA
LRA
S.F. Efficiency
Insulation
Voltage Frame PN ¹ Class
1
3
TEFC 230/460 56C V06742 3.7-3.6/1.8 3.99-3.8/1.9 11 1.25 75.5 B
Prem. Eff. TEFC 230/460 56C V06742PE 2.8/1.4 3.12/1.56 12.1 1.25 84.5 B
3
TEFC 230/460 56C V07742 4.9-4.6/2.3 5.3-5.1/2.54 18.4 1.15 80 B
Prem. Eff. TEFC 230/460 56C V07742PE 4.0/2.0 4.5/2.25 20.1 1.15 85.5 B
2* 3
TEFC 208-230/460 56C V08742 6.2-5.8/2.9 7.2-6.52/3.26 22 1.15 80 B
Prem. Eff. TEFC 208-230/460 56C V08742PE 5/4.75-2.5 6.4-5.8/2.9 30 1.15 86.5 B
3*
3
TEFC 208-230/460 56C V09742 8.1-7.6/3.8 9.5-8.6/4.3 32.9 1.15 82.5 F
Prem. Eff. TEFC 208-230/460 184TC V09742PE 6.8/3.4 8.5-7.7/3.8 32 1.15 88.5 F
5*
3
TEFC 208-230/460 184TC V10742A 13.2-12/6 15-13.6/6.8 47 1.15 85.5 F
Prem. Eff. TEFC 208-230/460 184TC V10742APE 11.2/5.7 14.4-13/6.5 55 1.15 90.2 F
7½*
3
TEFC 208-230/460 184TC V11742A 18.5/17.4 21.7-19.6/9.8 94 1.15 88.5 F
Prem. Eff. TEFC 230/460 213TC V11742APE 17.8/8.9 20.2/10.1 75 1.15 90.2 F
10*
3
TEFC 208-230/460 215TC V12742 25-24/12 30.5-27.6/13.8 105 1.15 85.5 F
Prem. Eff. TEFC 230/460 215TC V12742PE 23.8/11.9 27.6/13.8 112 1.15 89.5 F
15*
3
TEFC 208-230/460 254TC V13742 35/17.5 43-39/19.5 165 1.15 86.5 F
Prem. Eff. TEFC 208-230/460 254TC V13742PE 34.4/17.2 43.8-39.6/19.8 112 1.15 91.7 F
20 3
TEFC 208-230/460 256TC V14742 46/23 59.3-53.6/26.8 160 1.15 89.5 F
Prem. Eff. TEFC 208-230/460 256TC V14742PE 46/23 57.5-52/26 201 1.15 92.4 F
25 3
TEFC 230/460 284TC V15742 59/29.5 74.8-67.6/33.8 182 1.15 88.5 F
Prem. Eff. TEFC 230/460 284TC V15742PE 56/28 69.9-63.2/31.6 236 1.15 93 F
30 3
TEFC 230/460 284TC V16742 68/34 86.7-78.4/39.2 225 1.15 91 F
Prem. Eff. TEFC 230/460 286TC V16742PE 66/33 83.8-75.8/37.9 281 1.15 93 F
40 3
TEFC 230/460 284TC V17742 90/45 103.2/51.6 322 1.15 90.2 F
Prem. Eff. TEFC 230/460 324TSC V17742PE 90/45 102.2/51.1 286 1.15 93.6 F
50 3
TEFC 230/460 326TSC V18742S 112/56
141.8-128.2/64.1
430 1.15 92.4 F
Prem. Eff. TEFC 230/460 326TSC V18742SPE 108/54 124.8/62.4 422 1.15 94.1 F
NOTES:
¹ Locked rotor amps are for high voltage only.
* Currently available on Packaged Hydrovar.
• Motors are suitable for AQUAVAR
®
Variable Speed Drive.
Above data is for Baldor® TC and TSC frame motors. Specications subject to change without notice.
MOTOR DATA