Honeywell CT3650 Thermostat User Manual


 
69-128528
STEP 4. WIRE WALLPLATE TERMINALS
IMPORTANT
All wiring must comply with local codes and ordinances. If
unsure about household wiring procedures, call your local heat-
ing/air-conditioning contractor.
Refer to the labels
y
ou placed on the wires when
y
ou removed the old
thermostat (see illustration).
Match the letter of
y
our old thermostat wire with the correspondin
g
terminal letter on
y
our new thermostat. Refer to Table 2.
Remove the factor
y
-installed jumper connectin
g
terminals R and RC if
wires are connected to both of those terminals.
For wirin
g
dia
g
rams, if needed, see pp 21-22.
Loosen the terminal screws. Slip each wire beneath its matchin
g
terminal. Wraparound and strai
g
ht connections are both acceptable,
(see illustration). Ti
g
hten the terminals.
Plu
g
the hole in the wall with insulation to help prevent drafts from adversel
y
affectin
g
thermostat operation.
M16425
R
W
Y
G
M4826
FOR WRAPAROUND
INSERTION STRIP
7/16 IN. (11 MM).
FOR STRAIGHT INSERTION
STRIP 5/16 IN. (8 MM).