Honeywell HMR4007 Home Safety Product User Manual


 
HMR4007
SENSOR PRODUCTS
SPECIFICATIONS
Characteristics Conditions
Min Typ Max Units
General
Accuracy 0.2 0.1 mm
Resolution 0.1 mm
Hysteresis 0.01 mm
Repeatability 0.01 0.1 mm
Update Rate 10 30 Hz
Standoff
Distance (gap) between the target
magnet and the sensor board
0.1 5
(note 1)
mm
Magnetic Field
Range magnetic field at the sensor array 80(note 1) gauss
length apparent magnet length at sensor array 23
(note 3)
mm
Orientation Axial (note 2)
Electrical
Input Voltage Unregulated 6 28 VDC
Current 15 20 mA
Digital Interface
Baud Rate nonstandard synchronous serial interface 1000 21,000 Bits / sec.
Signaling Level TTL levels ( “1” )
( “0” )
3.5
-0.3
5.0
1.5
VDC
VDC
Connector In-Line 6-Pin Block (0.1” spacing)
Analog Interface
Analog Output D/A output 0 2.5 VDC
Update Rate 10 30 Hz
Signaling Level TTL levels ( “1” )
( “0” )
3.5
-0.3
5.0
1.5
VDC
VDC
Connector In-Line 4-Pin Block (0.1” spacing)
Physical
Dimensions Circuit Board Assembly
(including connectors)
40.0 x 80.0 x
12.0
mm
Weight HMR4007 16.5 grams
Environment
Temperature Operating
Storage
-40
-55
-
-
+70
+125
°C
Note 1: The standoff distance between the sensor board and the target magnet is highly variable. A magnet of sufficient strength,
however, must be used to maintain a magnetic field strength of 80 gauss (min.) at the sensor array and an apparent
magnet length of 23 mm.
Note 2: Sensor boards are factory calibrated in the axial mode using a 27mm cylindrical magnet. Operation in the radial mode
must be configured by the user.
Note 3: cf. "Magnet Considerations" (pg. 8)
Solid State Electronics Center
www.magneticsensors.com (800) 323-8295 Page 3