— 29 —
English
SERVICE AND REPAIRS
WARNING
•
Only service personnel trained by Hitachi, distributor or em-
ployer shall repair the Nailer.
•
Use only Hitachi parts supplied or recommended by Hitachi for
repair.
All quality Nailers will eventually require servicing or replacement
of parts because of wear from normal use.
In order to achieve the optimal performance of the NT50AGF Pneu-
matic Flooring Nailer, preventative Maintenance is recommended.
Manufacturer recommends replacement & re-greasing the Piston
O-Ring every 25,000 strokes (25,000 Nails). This will help prevent
premature wear and/or damage to the Piston & Cylinder and allow
the Nailer to be operated at the lower air pressure range.
Manufacturer recommends replacement & Lubrication of the O-
Rings in the Valve Body Assembly every 100,000 strokes (100,000
Nails). Again, this recommendation will help achieve longevity and
optimal performance of the NT50AGF Pneumatic Flooring Nailer.
NOTE:
Specifications are subject to change without any obligation
on the part of HITACHI.
Maintenance Chart
ACTION WHY HOW
Drain air line filter
daily
Prevent accumulation
of moisture and dirt.
Open manual petcock.
Clean filter element -
then blow air through
filter in direction oppo-
site to normal flow.
Prevent clogging of
filter with dirt.
Follow manufacturer’s
instructions.
Clean magazine and
feeder mechanism.
Prevent a jam. Blow clean daily.
Keep safety trigger
working properly.
Promote operator
safety and efficient
Tool operation.
Blow clean daily.
Drain air compressor. Keep the Nailer operat-
ing properly.
Open petcock on air
compressor tank.