Hellenbrand 1 Water System User Manual


 
9
Regeneration Mode
Typically a system is set to regenerate at a time of low water usage. An example
of a time with low water usage is when the household is asleep. If there is a demand
for water when the system is regenerating, untreated water will be supplied.
When the system begins to regenerate, the display will change to include
information about the step of the regeneration process and the time remaining for
that step to be completed. The system runs through the steps automatically and
will reset itself to provide treated water when the regeneration has been completed.
Manual Regeneration
Sometimes there is a need to regenerate the system, sooner than when the
system calls for it, usually referred to as manual regeneration. There may be
a period of heavy water usage because of guests or a heavy laundry day.
To initiate a manual regeneration at the preset delayed regeneration
time, press and release “REGEN”. The words “REGEN TODAY” will flash
on the display to indicate that the system will regenerate at the preset
delayed regeneration time. If you pressed the “REGEN” button in error,
pressing the button again will cancel the request.
To initiate a manual regeneration immediately, press and hold the “REGEN”
button for three seconds. The system will begin to regenerate immediately.
The request cannot be cancelled. You must cycle all the way through the cycles to make it stop. PLEASE NOTE: This will reset the meter.
Note: If the salt keeper does not contain salt. Fill with salt and wait at least two hours before regenerating.
Regeneration Step #2
(shows time remaining in regen step is 8:22)
Figure 11
SET SALT MONITOR OPTION
NOTE: This screen will not appear if system is set up as a filter or the 'set low salt
warning' is set to off. See dealer for details
Step 1US - Press the NEXT button until SALT appears in the display. It does not matter if the
SALT display alternates with the LBS REMAINING display.
Step 2US - Press SET CLOCK
Step 3US - Set LBS REMAINING: Use the or button to adjust the pounds remaining in
the brine tank.
NOTE: Estimate the pounds of salt in the brine tank and add it to the amount of salt added
to the brine tank. The example at the left would indicate 200 lbs. of salt being added to a
brine tank that has 40 lbs. remaining.
Step 4US - Press SET CLOCK to exit Adding Salt.
RETURN TO
NORMAL MODE
NOTE: The salt used per regeneration setting can be set in increments
of 0.1 pounds, but LBS REMAINING screen will round up or down to the
closet whole number.
Once the salt remaining as gone below the set point the display will
automatically flash Salt Fill.
Figure 10b