Hellenbrand 1 Water System User Manual


 
10
STEP 1S – Press NEXT and simultaneously for 3 seconds. If screen in Step
2S does not appear in 5 seconds the lock on the valve is activated.
STEP 2S – Choose SOFTENING using or button. Press NEXT to go to
Step 3S. Press REGEN to exit Softener System Setup.
STEP 3S – Select the time for the first cycle (which in this example is FILL)
using the or button. Press NEXT to go to Step 4S. Press REGEN to
return to previous step.
STEP 4S – Select the time for the second cycle (which in this example is
SOFTENING) using or button. Press NEXT to go to Step 5S. Press
REGEN to return to the previous step.
STEP 5S – Select the time for the third cycle (which in this example is BACK-
WASH) using the or button. Press NEXT to go to Step 6S. Press
REGEN to return to the previous step.
STEP 6S – Select the time for the fourth cycle (which
in this example is dn BRINE) using the or button.
Press NEXT to go to Step 7S. Press REGEN to return
to the previous step.
STEP 7S – Select the time for the fourth cycle (which in this example is dn
BRINE) using the or button. Press NEXT to go to Step 8S. Press
REGEN to return to the previous step.
CYCLE TIME ADJUSTMENTS
Normally it is not recommended to adjust the lengths of the cycle times. However, certain water conditions may
dictate adjustments. This should only be done from the recommendation of a water conditioning professional.
The following charts shows the upper and lower limits of each cycle.
STEP 1S
STEP 2S
Figure 12a
Cycle Options Units Lower/Upper Limit Factory Setting
Fill Lbs. 0.1 to 99.9 See Page 20
Softening (Service) Minutes 1 to 999 120
Backwash Minutes 1 to 999 8
Brine Minutes 1 to 999 60