Heatiator NNXT3933IL Indoor Fireplace User Manual


 
Heatilator • Novus NNXT • 4055-879 • Rev. o • 2/1218
5
5
Framing and Clearances
A. Select Appliance Location
When selecting a location for the appliance it is important
to consider the required clearances to walls (see Figure
5.1).
WARNING! Risk of Fire or Burns! Provide adequate
clearance around air openings and for service access. Due
to high temperatures, the appliance should be located out
of traf c and away from furniture and draperies.
NOTICE: Illustrations re ect typical installations and are
FOR DESIGN PURPOSES ONLY. Illustrations/diagrams
are not drawn to scale. Actual installation may vary due to
individual design preference.
In addition to these framing dimensions, also reference the
following sections:
Clearances and Mantel Projections (Sections 3.C. and 3.D.)
Vent Clearances and Framing (Section 6)
Rear vent
One 45° elbow
Horiz Term
Rear Vent
Two 90° elbows
Horiz Term
Rear Vent
One 90° elbow
Vert Term
Top Vent
One 90° elbow
Horiz Term
No elbows
Horiz Term
A
A
A
A
A
A
C
B
B
E
F
D
1/2 in. (13 mm) min.
appliance to
combustibles
D
F
1 in. (25 mm)
min. pipe to
combustibles
E
1/2 in. (13 mm)
min. appliance
to combustibles
Alcove
Installation
C
1 in. (25 mm)
min. pipe to
combustibles
G
Drywall
48 in.
(1219 mm)
maximum
ABCDEFG
in.
39 35-1/ 2 19-5/ 8 43-3/ 8 47 53-1/ 4 40
mm
991 902 498 1102 1194 1353 1016
in.
42 37-5/ 8 19-5/ 8 43-3/ 8 47 53-1/ 4 43
mm
1067 956 498 1102 1194 1353 1092
Model
NNXT3933
NNXT4236
Figure 5.1 Appliance Locations