Heatcraft Refrigeration Products 25005601 Humidifier User Manual


 
15
Wall Mount Back Bar Unit Cooler
Dimensional Diagram
Mounting
The Wall Mount Back Bar Unit Cooler is a low height unit designed for undercounter applications. Air is drawn in at the
bottom of the unit and discharged out the front. Two mounting angles are included with the unit and should be installed
to space the unit 3/4” off the wall. Air deflector(s) are included and can be mounted over the top half of the fan guard
to direct the air up. The deflector may be left off if total horizontal air movement is desired. If used, the deflector can be
field formed to direct the air where needed. Locating holes and screws are provided.
Dimensional Data
Approx.
Model BTUH Motor Data Dimensions (In.) Ship Wt.
BB 10°F TD CFM Qty. HP W A B C D E F
(Lbs.)
L10 1,000 90 1 1/150 19
3
/
4
19
1
/
8
18 17
1
/
2
7
1
/
16
- 16
5
/
8
17
M11 1,100 90 1 1/150 19
3
/
4
19
1
/
8
18 17
1
/
2
7
1
/
16
- 16
5
/
8
16
L15 1,500 180 2 1/150 26
1
/
4
25
5
/
8
24
1
/
2
24 4
13
/
16
8
5
/
8
23
1
/
8
20
M16 1,600 180 2 1/150 26
1
/
4
25
5
/
8
24
1
/
2
24 4
13
/
16
8
5
/
8
23
1
/
8
19
Low -10°F Sat. Suction Temp. -15°F Sat. Suction Temp.
Temp BTUH @ R-404A BTUH @ R-404A
Model 10°F TD Alco Sporlan 15°F TD Alco Sporlan
BBL10 1000
HFS-1/8SZ EFS-1/8Z
1500 HFS-1/8SZ EFS-1/8Z
BBL15 1500 2250 HFS-1/4SZ EFS-1/6Z
Med 25°F Sat. Suction Temp. 20°F Sat. Suction Temp.
Temp BTUH @ R-22 BTUH @ R-22
Model 10°F TD Alco Sporlan 15°F TD Alco Sporlan
BBM11 1100
HFS-1/4HC EFV-1/5C
1870
HFS-1/4HC EFV-1/5C
BBM16 1600 2720
Expansion Valve Recommendations
Replacement Parts
Description All Sizes Part No.
115V Motor 25300701
208/230V Motor 25300801
Fan Blade 5101B
Fan Guard 5054D
Motor Mount 91179001
NOMENCLATURE
BB L S 10 A G
A = 115-1-60
B = 208/230-1-60
Revision
Back Bar Unit
Cooler
L = Low Temp Unit
M = Med. Temp Unit
Size
Blank = Std. Unit
S = Slave Unit
M = Master Unit
FOR FOOD
SERVICE
INSTALLATIONS
. . . seal any joint
between unit cooler
and cooler liner
with a sealant
listed by the
National Sanitation
Foundation,
Standard 51
NOTE: All units have 3/8 O.D. suction, 1/2 O.D. sweat inlet connection and 1/2 O.D. drain.