Step 9
Wiring the
Fireplace
NOTE: Electrical wiring must be installed by a
licensed electrician.
Caution: Disconnect remote controls if you are
absent for extended time periods. This will
prevent accidental fireplace operation.
Appliance Requirements
This appliance DOES NOT require 110-120 VAC
to operate.
WARNING
DO NOT CONNECT 110-120 VAC TO
THE GAS CONTROL VALVE WALL
SWITCH OR THE APPLIANCE WILL
MALFUNCTION AND THE VALVE WILL
BE DESTROYED.
Optional Accessories
Optional remote control kits require that 110-120
VAC be wired to the factory installed junction box
before the fireplace is permanently installed.
Wall Switch
Position the wall switch in the desired position on a
wall. Run a maximum of 25 feet (7.8 m) or less
length of 18 A.W.G. minimum wire and connect it to
the fireplace ON/OFF switch pigtails.
WARNING
DO NOT CONNECT 110-120 VAC TO
THE WALL SWITCH OR THE CONTROL
VALVE WILL BE DESTROYED.
CAUTION
LABEL ALL WIRES PRIOR TO
DISCONNECTION WHEN SERVICING
CONTROLS. WIRING ERRORS CAN CAUSE
IMPROPER AND DANGEROUS OPERATION.
VERIFY PROPER OPERATION AFTER
SERVICING.