Heat & Glo LifeStyle Montana-42 Indoor Fireplace User Manual


 
Heat & Glo LifeStyles Collection • Montana • 4039-150 Rev I • 08/06
23
8
8
Finishing
A. Hearth Extension
A hearth extension must be installed with all replaces to
protect the combustible oor in front of the replace from
both radiant heat and sparks. See Figures 8.1 -8.3.
2 in. (51 mm)
required
High temperature
(300°F min.) continuous,
non-combustible sealant
Tile, stone or other
non-combustible material
Floor constructed of wood or
other combustible material
HX3 or HX4
Hearth Ext
or equivilent
insulation
(see Table below)
Fireplace
Protective
Metal Hearth
Strip
Figure 8.1 Hearth Extension Construction
1 in. (25 mm) overlap
Metal strips are placed 2 in. (51 mm) under the front
of the fireplace and must extend beyond the front
and sides of fireplace opening by 2 in. (51 mm).
Figure 8.2 Positioning the Protective Metal Hearth Strips
The hearth extension should slope away from the front of the
replace and chase at 1/8 in. to 1/4 in. per foot. Spark strips
must be used on top of any combustible hearth materials
used for moisture management.
This replace has been tested and approved for use with a
hearth extension insulated to a minimum R value of 1.16.
To substitute materials for the factory-available hearth ex-
tensions, see Figure 8.3 and calculate insulation alterna-
tives as per Table 8.1 and the following formulas:
Thermal conductivity per inch thickness = k
k = (BTU)(inch) / (foot
2
)(hour)(°F)
Required thickness = Rk
Thermal resistance per inch thickness = r
r = (foot
2
)(hour)(°F) / (BTU)(inch)
Required thickness = R / rB.
A
B
C
Figure 8.3 Hearth Extension Dimensions
Fire Risk
Metal hearth strips MUST be installed.
Sparks or embers may ignite ooring.
WARNING
Fire Risk
Hearth extensions must be installed
exactly as speci ed.
High temperatures or hot embers may ignite
concealed combustibles.
WARNING
Table 8.1
Hearth Extension Insulation Alternatives, R Value = 1.16
Material
k per inch
thick
r per inch
thick
Minimum
thickness
required
Hearth & Home HX3, HX4 0.43 2.33 1/2 in.
USG Micore 300™ 0.46 2.18 1/2 in.
USG Durock™ Cement Board 1.92 0.52 2-1/4 in.
Cement Mortar 5.0 0.20 5-7/8 in.
Common Brick 5.0 0.20 5-7/8 in.
Ceramic Tile 12.50 0.08 14-5/8 in.
Armstrong™ Privacy Guard
Plus 0.46 3.28 1/2 in.
Marble 14.3-20.0 0.07-0.05 16-5/8 in. - 23-3/8 in.
CAT. # A B
HX3 in 52 16
mm 1321 406
HX4 in 66 20
mm 1676 508