Heat & Glo LifeStyle Montana-42 Indoor Fireplace User Manual


 
Heat & Glo LifeStyles Collection • Montana • 4039-150 Rev I • 08/06
15
A. Chimney Requirements
Vertical distances are measured from the base of the re-
place as shown in Figure 5.2.
To determine the chimney components needed to complete
your particular installation, follow the steps below:
Determine the total vertical height of the fireplace
installation. This dimension is measured from the base of
the replace assembly to the point where the smoke exits
the termination cap.
Subtract the effective height of the replace assembly from
the overall height of the replace installation (measured
from the base of the fireplace to the bottom of the
termination cap).
Refer to Table 5.1 to determine what components must
be selected to complete the replace installation.
Determine the number of ceiling restops, stabilizers,
roof flashing, etc. required to complete the fireplace
installation.
Table 5.1
Do NOT connect this fireplace to a chimney flue
servicing another appliance.
Do NOT connect to any air distribution duct or
system.
CAUTION
Fire Risk
Must maintain 2 in. (51 mm) air clearance
to insulation and other combustible
materials.
WARNING
Note: A maximum of two pairs of offsets and returns may
be used.
5
5
Chimney Assembly
HEIGHT OF CHIMNEY COMPONENTS in. mm
Chimney Stabilizer
SL11 4-3/4 121
Ceiling Firestops
FS538 0 0
FS540 0 0
Offsets/Returns
SL1130 18 457
Roof Flashing
RF570 0 0
RF571 0 0
Chimney Sections*
SL1106 4-3/4 121
SL1112 10-3/4 273
SL1118 16-3/4 425
SL1136 34-3/4 883
SL1148 46-3/4 1187
* Dimensions re ect effective height.
ft m
Minimum overall straight height 14 4.27
Minimum height with offset/return 16 4.88
Maximum height 90 27.43
Maximum chimney length between an offset
and return
20 6.1
Maximum distance between chimney
stabilizers
35 10.67
Double offset/return minimum height 24 7.32
Maximum unsupported chimney length
between the offset and return
6 1.83
Maximum unsupported chimney height above
the replace
35 10.67
Minimum overall straight height if replace is
freestanding
6.33 1.93