Heat & Glo LifeStyle Montana-42 Indoor Fireplace User Manual


 
Heat & Glo LifeStyles Collection • Montana • 4039-150 Rev I • 08/06
21
2 in. (51 mm) min.
4-1/2 in.
(114 mm)
max.
1-1/2 in.
(38 mm) min.
overlap
Cap Standoff
Top of Pipe
Flashing Collar
Figure 6.5 Installing an ST1175 Square Termination Cap
The last section of pipe
must stop between the
distances given below.
2 in. (51 mm) above top
of the chase.
7 in. (178 mm) below top
of the chase.
{
Top of Pipe
1-1/2 in. (38 mm)
min. overlap
Figure 6.6 Installing a TCT1175 Terra Cotta Cap
For installations utilizing an ST1175 Square Termination
Cap the last chimney section must not be more than
4-1/2 in. (114 mm) below the chase top. See Figure 6.5.
For installations utilizing an TCT1175 Terra Cotta Cap the
last chimney section must be between 7 in. (178 mm) below
the chase top and 2 in. (51 mm) above. See Figure 6.6.
For chase installations you can use a TR11 Round
Termination Cap, a TR11T Round Telescoping Termination
Cap, an ST1175 Square Termination Cap, or a TCT1175
Terra Cotta Termination Cap.
Install termination caps following instructions provided
with them.