Heat & Glo LifeStyle 8000TVC Indoor Fireplace User Manual


 
14
NOTE: Electrical wiring must be installed by a
licensed electrician.
Caution: Disconnect remote controls if you
are absent for extended time periods. This
will prevent accidental fireplace operation.
For Standing Pilot Ignition Wiring
Appliance Requirements
This appliance DOES NOT require 110-120
VAC to operate.
WARNING
DO NOT CONNECT 110-120 VAC TO
THE GAS CONTROL VALVE OR THE
APPLIANCE WILL MALFUNCTION AND
THE VALVE WILL BE DESTROYED.
Optional Accessories
Optional fan and remote control kits require that 110-
120 VAC be wired to the factory installed junction
box before the fireplace is permanently installed.
Remote Wall Switch
Position the remote wall switch in the desired
position on a wall. Run a maximum of 25 feet (7.8
m) or less length of 18 A.W.G. minimum wire and
connect it to the fireplace ON/OFF switch pigtails.
WARNING: DO NOT CONNECT 110-120
VAC TO THE REMOTE WALL SWITCH
OR THE CONTROL VALVE WILL BE
DESTROYED.
CAUTION
LABEL ALL WIRES PRIOR TO DISCONNECTION
WHEN SERVICING CONTROLS. WIRING
ERRORS CAN CAUSE IMPROPER AND
DANGEROUS OPERATION. VERIFY PROPER
OPERATION AFTER SERVICING.
Figure 10. Standing Pilot Ignition Wiring Diagram
Step 9
Wiring the
Fireplace