B. Facing Material
Metal front faces may be covered with non-combustible
materials only.
• Facing and/or nishing materials must not interfere with
air ow through louvers, operation of louvers or doors,
or access for service.
• Facing and/or nishing materials must never overhang
into the glass opening.
• Observe all clearances when applying combustible
materials.
• Seal joints between the nished wall and appliance top
and sides using a 300ºF minimum sealant. Refer to
Figure 13.3.
WARNING! Risk of Fire! DO NOT apply combustible
materials beyond the minimum clearances. Comply with
all minimum clearances to combustibles as speci ed in
this manual. Overlapping materials could ignite and will
interfere with proper operation of doors and louvers.
Figure 13.5 Noncombustible Facing Diagram
B
A
FACTORY-INSTALLED NON-COMBUSTIBLE BOARD
DO NOT REMOVE
AB
6000
inches 39-3/4 41
millimeters 1010 1041
8000
inches 41-3/4 48
millimeters 1060 1219
C. Finish and Sealing Joints
All joints between the nished wall sheathing and the ap-
pliance must be sealed with non-combustible materials.
Sealants, such as caulk or mastic used to seal the gap
between the wall and the replace, should be rated at a
minimum continuous exposure to 300ºF.
Finishing Around Opening with Gypsum Wallboard
Gypsum wallboard (drywall) joints adjacent to the re-
place opening, including the non-combustible board on
the appliance, require special attention to minimize crack-
ing. When installing gypsum wallboard around the re-
place, install the hole for the replace opening in a single
wallboard sheet, if possible. This will minimize the joints
adjacent to the replace opening.
Tape wall board joints around the replace opening with
berglass-mesh tape. It will provide a more crack-resis-
tant joint than paper tape. Fill, smooth and nish wall
joints with chemically setting-type joint compound. It will
provide a more crack-resistant joint than air-drying light-
weight compound.
Painting
If desired nishing includes a painted wall, 100% acrylic
latex with compatible primer is recommended around this
appliance. Oil-based or standard acrylic paints may dis-
color due to heat exposure.