Heat & Glo LifeStyle 6000CMOD-IPI Indoor Fireplace User Manual


 
35
Heat & Glo • 6000CMOD-IPI, 8000CMOD-IPI • 2241-900 Rev. H • 5/12
9
9
Appliance Preparation
CAUTION! Risk of Cuts, Abrasions or Flying Debris.
Wear protective gloves and safety glasses during instal-
lation. Sheet metal edges are sharp.
A. Top Vent
Figure 9.1 Cut the seal cap strap across the rectangles
next to the disk. For rear vent, skip this step.
Figure 9.2 Remove the white gasket material covering
the seal cap.
Figure 9.4 Remove the insulation basket and white insu-
lation from the center vent pipe.
Figure 9.5 Remove the insulation from the outer vent
pipe. For rear venting there is no insulation in the outer
vent pipe.
Figure 9.3 Remove the seal cap.
Figure 9.6 To attach the rst section of vent pipe, make
sure to use the berglass gasket in the manual bag to seal
between the rst vent component and the outer replace
wrap. Use 2 self tapping screws to secure the gasket to
the outer wrap.
Secure the rst section of venting to the replace by screw-
ing through the two straps left over from cutting the seal
cap strap in step 2.