Heat & Glo LifeStyle 6000C Indoor Fireplace User Manual


 
Heat & Glo • 6000C, 6000C-IPI, 8000C, 8000C-IPI • 2164-900 Rev. T • 9/12
29
H
2
H
1
V
2
V
1
Figure7.5
TopVent-HorizontalTermination-(continued)
ThreeElbows
V
1
Min. H
1
Max. V
2
Min. H
2
Max.
Elbow only 2 ft. 610 mm 0 in. 0 mm 1 ft. 305 mm
6 in. 152 mm 3 ft 914 mm 6 in. 152 mm 2 ft. 610 mm
1 ft. 305 mm 6 ft. 1.8 m 1 ft. 305 mm 6 ft. 1.8 m
2 ft. 610 mm 11 ft.* 3.4 m* 2 ft. 610 mm 10 ft.* 3.1 m*
3 ft. 914 mm 16 ft * 4.9 m* 3 ft. 914 mm 14 ft.* 4.3 m*
*H
1
+ H
2
= 20 ft. (6.1 m) Maximum V
1
+ V
2
+ H
1
+ H
2
= 40 ft. (12.2 m) Maximum
INSTALLED
HORIZONTALLY
H
1
H
2
V
1
Figure7.4
TwoElbows
Note: For corner installations: A 6 inch
(152 mm) section of straight pipe may
need to be attached to the appliance
before a 90º
elbow, to allow the vent
pipe to clear the top standoffs.
6000C-IPI
V
1
Minimum H
1
+H
2
Maximum
Elbow only Not allowed
6 in. 152 mm 2 ft. 610 mm
1 ft. 305 mm 4 ft. 1.2 m
1-1/2 ft. 457 mm 11 ft. 3.4 m
2 ft. 610 mm 19 ft. 3.8 m
2-1/2 ft. 762 mm 22 ft. 6.7 m
V
1
+ H
1
+ H
2
= 40 ft. (12.2 m) Maximum
H
1
+ H
2
= 22 ft. (6.7 m) Maximum
V
1
= 1 ft. (305 mm) Minimum
8000C-IPI
V
1
Minimum H
1
+H
2
Maximum
Elbow only Not allowed
6 in. 152 mm Not allowed
1 ft. 305 mm 2 ft. 610 mm
2 ft. 610 mm 4 ft. 1.2 m
3 ft. 914 mm 6 ft. 1.8 m
4 ft. 1.2 m 8 ft. 2.4 m
6 ft. 1.8 m 12 ft. 3.6 m
10 ft. 3.0 20 ft. 6.1 m
V
1
+ H
1
+ H
2
= 40 ft. (12.2 m) Maximum
H
1
+ H
2
= 20 ft. (6.0 m) Maximum
V
1
= 1 ft. (305 mm) Minimum