Heat & Glo LifeStyle 6000 XLT Indoor Fireplace User Manual


 
8
Step 3
Installing the
Vent System
A. Vent System Approvals
Models 8000DVTFL, 6000DVTFL, 6000XLT, and
6000ARCH are approved to use D-series direct vent
pipe components and terminations. Model SL-
42DVT is approved to us SL-D-series components
and terminations. Approved vent system components
are labeled for identification. NO OTHER VENTING
SYSTEMS OR COMPONENTS MAY BE USED.
Detailed installation instructions are included with
each vent termination kit and should be used in
conjunction with this
Installers Guide
. The drawing
below shows vent system components and
terminations.
Identifying Vent Components
The vent systems installed on this gas fireplace may
include one, two, or three 90°
elbow assemblies. The
relationships of vertical rise to horizontal run in vent
configurations using 90° elbows MUST BE strictly
adhered to. The rise to run relationships are shown in
the venting drawings and tables. Refer to the
diagrams on the next several pages.
Figure 6. Vent Components and Terminations
HORIZONTAL
TERMINATION
HORIZONTAL
TERMINATION
WALL FIRESTOP
90 DEGREE
ELBOW
90 DEGREE
ELBOW
VERTICAL
TERMINATION
VERTICAL
TERMINATION
STORM COLLAR
ROOF FLASHING
HORIZONTAL PIPE
SUPPORT
HORIZONTAL PIPE
SUPPORT
PIPE LENGTH
WALL BRACKET
CEILING
FIRESTOP
CEILING
FIRESTOP
TERMINATION KITS
DVK-01D
DVK-02D
DVK-01D
DVK-02D
DVK-TVCD
DVK-01SD
DVK-02SD
DVK-01SD
DVK-02SD
DVK-01TRD
DVK-02TRD
DVK-01TRD
DVK-02TRD
COMPONENT IDENTIFICATION
Vent system components
Vent system
termination kits
D-SERIES
TERMINATIONKITS
SLK-01D
SLK-TVCD
SLK-991D
SLK-TVCD
SLK-991D
SLK-01TRD
SL-D-SERIES