APPROVED VERTICAL
TERMINATION VENTING
CONFIGURATIONS WITH NO
ELBOWS OR (2) 45
0
OFFSETS,
FIGURE 14, AND (2) 90
0
ELBOWS,
FIGURE 15.
10' minimum system height (with or
without offsets)
35' maximum system height
6' maximum offset (refer to Figure 14)
11' maximum offset (refer to Figure 15)
The termination must fall within the
Outline shown in the Figures 14 & 15.
Use the indicated restriction plate
position. The Restriction Plate part # is
5950-922.
Figure 15: Vertical Termination Using (2) 90º
Elbows
Figure 14: Vertical Terminations Using Straight
Pipe
Clearances from the pipe to
combustibles:
1" to vertical runs
1" below and to the side of
horizontal runs
2" from the top of horizontal runs