Hearth and Home Technologies Tucson (8700) Indoor Fireplace User Manual


 
HearthStone Quality Home Heating Products Inc Tucson Model #8700
13
INSTALLERS
INFORMATION
CODES
Adhere to all local codes or, in their
absence, the latest edition of THE
NATIONAL FUEL GAS CODE ANSI
Z223.1 (NFPA 54) or CAN/CGA B149
Installation Code that can be obtained from:
AMERICAN NATIONAL STANDARDS
INSTITUTE, INC.
1430 BROADWAY
NEW YORK, NY 10018
OR
NATIONAL FIRE PROTECTION
ASSOCIATION, INC.
BATTERY MARCH PARK
QUINCY, MA 02269
The appliance when installed, must be
electrically connected and grounded in
accordance with local codes or, in the
absence of local codes, with the current
NFPA 70-National Electrical Code or CSA
C22.1-Canadian Electric Code.
A manufactured home (mobile) OEM
installation must conform with the
Manufactured Home Construction and
Safety Standard, Title 24 CFR, Part 3280
(U.S.) or Standard for Manufactured Home
Installation, ANSI/NCBCS A225.1 or
Standard for Gas Equipped Recreational
Vehicles and mobile Housing, CSA
Z240.4.CAN/SCA Z240 MH (Canada).
(Installer l’appareil selon les codes ou
règlements locaux, ou, en l’absence de tels
règlements, selon les Codes d’installation
CAN/CGA-B149.)
ITEMS REQUIRED FOR
INSTALLATION
* External regulator (for propane/L.P.G.
only)
* Piping which complies with local codes
* Pipe sealant approved for use with
propane/L.P.G. (resistant to sulfur
compounds)
* Manual shutoff valve
* Sediment trap
* Tee joint
* Pipe wrench
* Phillips head screwdriver
* Other parts as required by local code
*Safety Glasses
*Gloves
PACKING LIST
1-Tucson Gas-Fired Heater
2-Decorative Ceramic Fiber Logs
2-Ember Screen
1-Charcoal Embers
1-Owner’s Manual
1-Thermostat
1-40’ Thermostat wire
1-L.P. Fuel Conversion Kit
1-Warranty Validation Form
1-Exhaust Restrictor Kit
Note: Vent kits are supplied separately.
Failure to use the venting components
suggested by HearthStone will void your
warranty.