1. Place the fireplace
into position.
2. Level the fireplace
from side to side and
from front to back.
3. Shim the fireplace
with non-combus-
tible material, such
as sheet metal, as
necessary.
4. Secure the fireplace
to the framing by
nailing or screwing.
Figure 38. Proper Positioning, Leveling, and
Securing of a Fireplace
Step 5
The Gas Control
System
WARNING: THIS UNIT IS NOT FOR
USE WITH SOLID FUEL.
Standing Pilot Ignition System
This system includes millivolt control valve,
standing pilot, thermopile/thermocouple flame
sensor, and piezo ignitor.
WARNING: 230 VAC MUST NEVER BE
CONNECTED TO A CONTROL VALVE
IN A MILLIVOLT SYSTEM.
The diagram below shows how to properly
position, level, and secure the fireplace.
Step 4
Positioning,
Leveling, and
Securing the
Fireplace
STANDING PILOT
Figure 39. Gas Control System
!
!
NAILING TABS
BOTH SIDES