Hearth and Home Technologies RBV4236IT Indoor Fireplace User Manual


 
8 Heatilator • RBV4236/RBV4842 • 4048-210 Rev K • 02/07
Note:
• Illustrations re ect typical installations and are FOR
DESIGN PURPOSES ONLY.
Illustrations/diagrams are not drawn to scale.
Actual installation may vary due to individual design
preference.
Fire Risk
Provide adequate clearance:
Around air openings.
For service access.
Locate appliance away from traf c areas.
WARNING
A. Select Appliance Location
When selecting a location for your appliance it is important to
consider the required clearances to walls (See Figure 3.1).
Note: For actual appliance dimensions refer to
Section 16.
In addition to these framing dimensions, also reference the
following sections:
Clearances and Mantel Projections (Sections 3.C. and 3.D.)
Vent Clearances and Framing (Section 6)
A
A
A
C
B
B
1/2 in. (13 mm) min.
appliance
to combustibles
Alcove
Installation
C
Drywall
48 in.
(1219 mm)
max.
1 in.
(25 mm)
min.
Figure 3.1 Appliance Locations
3
3
Framing and Clearances
Model # A B C
RBV4236 in. 42 48 22
mm 1067 1219 559
RBV4842 in. 48 51-1/4 22
mm 1219 1327 559