Ignitor
Flame
Sensor
Pilot Assembly
GRN
ORG
BLK
ORG
Control
Box
To
Junction
Box
Battery
Pack
3V
Adaptor
BLK
BRN
RED
RED
BLK
BLU
Valve
Limit
Switch
WHT
+
-
+
-
Wall Switch
WHT
GRN*
*
GRN wire only used with
optional wall switch
WSK-MLT-HTL
Figure 10.2 Intelli re Pilot Ignition (IPI) Wiring Diagram
Battery polarity must be correct or module damage will
occur.
CAUTION
C. Intelli re Ignition System Wiring
This appliance requires a 110 VAC supply to the appliance
junction box for operation. A wiring diagram is shown in Fig-
ure 10.2.
This appliance is equipped with an Intelli re control valve
which operates on a 3 volt system.
This appliance is supplied with a battery pack and a 3 volt
AC transformer, which requires the installation of the sup-
plied junction box. It is highly recommended that the junction
box be installed at this time to avoid reconstruction.
The battery pack requires two D cell batteries (not included).
Batteries cannot be placed in the battery pack while using
the 3 volt AC transformer. Conversely, the transformer must
be unplugged if the battery pack is used.
Optional Accessories Requirements
Wiring for optional accessories should be done now to
avoid reconstruction.
Label all wires prior to disconnection when servicing
controls. Wiring errors can cause improper and dangerous
operation. Verify proper operation after servicing.
CAUTION
Shock Risk
Replace damaged wire with type 105° C
rated wire.
Wire must have high temperature
insulation.
CAUTION
BLACK
WHITE
GROUND
14-2 with
Ground Romex