28 Heatilator • RBV4236/RBV4842 • 4048-210 Rev K • 02/07
Handle glass with care.
• Inspect the gasket to ensure it is
undamaged.
• Inspect the glass for cracks, chips or
scratches.
• Do NOT strike, slam or scratch glass.
• Do NOT operate appliance with glass
assembly removed, cracked, broken or
scratched.
• Replace glass assembly as a complete
assembly.
WARNING
H. Hood
The hood is shipped on top of the outer shell of the appli-
ance. Remove the hood from its shipping location. Locate
the four hood retaining clips and slide the hood into them.
The hood must be attached or a fi re hazard may result. See
Figure 12.13.
Figure 12.13 Installing the Hood
G. Glass Doors
Note: Glass doors are not optional in the Commonwealth
of Massachusetts. They are required.
If you have decided to install optional doors on your appli-
ance, please use them correctly. While operating your appli-
ance, you should either have the doors completely open or
completely closed, but never partially open.
Fire Risk
Combustion Fumes Risk
• Appliances equipped with optional glass
doors must be operated with doors fully
open or fully closed.
• Only use glass doors certifi ed for use with
this appliance.
If doors are left partially open, gas and
fl ames may be drawn out of the appliance
opening.
WARNING
Screws for DM Door Installation
Figure 12.14 Pins & Screws for DM Door Installation - Reveal
• DM1036 or DM1042 door installation on the RBV4236
or RBV4842 requires longer pins. The longer pins and
screws to attach them are located on the valve bracket
of the appliance. See Figure 12.14.
Figure 12.15 Install Pins
• Remove the shorter door pins using a phillips screwdriver
and replace them with the longer pins. See Figure