Heatilator • RBV4236/RBV4842 • 4048-210 Rev K • 02/07 27
F. Log Removal/Replacement
The log set should look similar to that in Figure 12.8.
Figure 12.8 Reveal Log Set
Figure 12.10 Remove Hearth Refractory - Step 1
Figure 12.11 Remove Hearth Refractory - Step 2
• Brush the lava rock away from the hearth refractory as
shown in Figure 12.9.
Figure 12.12 Remove Screws From Sides
• Remove log/grate assembly from the hearth pan by
removing two screws (one per side). See Figure 12.12.
• Lift up on log/grate assembly to remove it from appliance
and set aside.
• Reverse the order to reinstall the log/grate assembly.
Figure 12.9 Clear Lava Rock
• Remove/open the hearth refractory as shown in
Figures 12.10 and 12.11.