Heatilator • RBV4236/RBV4842 • 4048-210 Rev K • 02/07 21
A. Recommendation for Wire
This appliance requires 110-120 VAC to be wired to the junc-
tion box for use of optional accessories and for proper op-
eration of the appliance.
Shock Risk
Explosion Risk
Do NOT wire 110V to valve.
Do NOT wire 110V to wall switch
• Incorrect wiring will damage millivolt
values.
• Incorrect wiring will override IPI safety
lockout and may cause explosion.
WARNING
10
10
Electrical Information
Note: This appliance must be elecrtrically wired and
grounded in accordance with local codes or, in the absence
of local codes, with National Electric Code ANSI/NFPA
70-latest edition or the Canadian Electric Code, CSA
C221.1.
B. Connecting to the Appliance
• This appliance may be used with a wall switch, wall
mounted thermostat and/or a remote control.
• Follow parameters for locating thermostat (see individual
thermostat instructions) to ensure proper operation of
appliance.
• Use low resistance thermostat wire for wiring from ignition
system to the wall switch and thermostat.
• Keep wire lengths short as possible by removing any
excess wire length.
• Low voltage and 110 VAC voltage cannot be shared within
the same wall box.