Hearth and Home Technologies RBV4236IT Indoor Fireplace User Manual


 
Heatilator • RBV4236/RBV4842 • 4048-210 Rev K • 02/07 21
A. Recommendation for Wire
This appliance requires 110-120 VAC to be wired to the junc-
tion box for use of optional accessories and for proper op-
eration of the appliance.
Shock Risk
Explosion Risk
Do NOT wire 110V to valve.
Do NOT wire 110V to wall switch
Incorrect wiring will damage millivolt
values.
Incorrect wiring will override IPI safety
lockout and may cause explosion.
WARNING
10
10
Electrical Information
Note: This appliance must be elecrtrically wired and
grounded in accordance with local codes or, in the absence
of local codes, with National Electric Code ANSI/NFPA
70-latest edition or the Canadian Electric Code, CSA
C221.1.
B. Connecting to the Appliance
This appliance may be used with a wall switch, wall
mounted thermostat and/or a remote control.
Follow parameters for locating thermostat (see individual
thermostat instructions) to ensure proper operation of
appliance.
Use low resistance thermostat wire for wiring from ignition
system to the wall switch and thermostat.
Keep wire lengths short as possible by removing any
excess wire length.
Low voltage and 110 VAC voltage cannot be shared within
the same wall box.