Page 30
Heat & Glo • NorthStar EPA Fireplace • 480-1081C
September 1, 2008
September 1, 2008
September 1, 2008
7
Accessories
A. Fan Replacement
Screwdriver Slot
Screws
Unplug wire
harness before
removing fan
Remove nut
and lift out fan
Fan Cord Location
The NorthStar Fireplace comes standard equipped with two
fans, installed at the factory with electric access on the right
sideofreplace(asyoufaceit).
Shock Risk
CirculatingFireplaceOnly
• DoNOT removegrounding prong from
plug.
CAUTION
• Plug directly into properly grounded three-prong
receptacle.
• Route cord away from appliance.
•
DoNOTroutecordunderorinfrontofappliance.
Figure 30.1 Accessing Fan Motor
Figure 30.2 Fan Motor
Removing the Fan
1. Unplug the wire harness.
2. Lift fan from locating pins and remove. Repeat for second
fan if necessary. See Figure 30.2.
3. Inspect the gasket and ensure it is in good condition.
4. Connect new fan wires to wire harness.
5. Before installing the fan, make sure the grommets are
tightly in place. Insert the right fan and place over the 2
locating pins. Repeat for other fan. Figure 30.3.
Fan Replacement Instructions
1.Removethebrickfromthebottomofthereplaceand3
of the back vertical bricks.
2.Removethe2screwsfromtheaccesspanelinthere-
boxoor.SeeFigure30.1.
3. Pry up the access panel using the screwdriver slot and
completely remove the panel.
Figure 30.3 Installing Fans
6. Re-install bottom panel or rebox access panel in
reverse order as described above.
7 Replace the brick that was removed.
8. Reconnect the power.
Shock Risk
Disconnect power by turning off circuit breaker
BEFORE servicing.
CAUTION