Hearth and Home Technologies EL42 Indoor Fireplace User Manual


 
18
6
Framing & Clearances
G
F
E
A
C
Across a
corner
H
As a
room
divider
D
48 in.
(1219 mm)
minimum
A
Along a wall
A
B
5/8 in. (16 mm) all
configurations
H
1/2 in. (13 mm) min. air
space from fireplace to
combustible materials.
Note:
Note:
In addition to these
framing dimensions,
also reference the
following sections:
Clearances (Section
6.B.)
Mantel Projections
(Section 11.E.)
Fireplace Dimensions
(Section 13.A.)
H
B
In an exterior chase
or projecting into a
garage
A
Note: Measurements are FRAMING dimensions only and do
not include drywall either in the cavity or on the interior walls.
I
I
A B C D E F G H I
inches
42 50 67 7/8 59 1/2 34 14 48 21 1/2
mm
1067 1270 1724 1511 864 356 1219 546
inches
48 56 73 7/8 65 1/2 37 1/4 14 52 1/4 21 1/2
mm
1219 1422 1876 1664 946 356 1327 546
Model
12 in. (305 mm)
Minimum from FP
opening to any
perpendicular wall.
EL36
EL42
Figure 6.1 Fireplace Locations (Framing dimensions shown)
A. Select Fireplace Location
Heatilator • EL36/EL42 • 4044-132 • Rev AD • 7/12