Hearth and Home Technologies EL42 Indoor Fireplace User Manual


 
13
4
Troubleshooting Guide
Start Fire Problems Possible Cause Solution
Can’t get re started
Excessive smoke or spillage
Burns too slowly
Smolders, sizzles
Not enough kindling/paper or no
kindling/paper
Use dry kindling, more paper. Arrange kindling &
wood for air movement.
Not enough air for re to ignite Check for restricted cap/shroud.
Check for ue blockage.
Pre-warm ue before starting re
Check for adequate vent height (refer to chimney
assembly section).
Wood condition is too wet, too
large
Use dry, seasoned wood
Bed of coals not established
before adding wood
Start with paper & kindling to establish bed of
coals (refer to starting re section).
Flue blockage such as birds’ nests
or leaves in termination cap
Have chimney inspected for creosote and cleaned
by a certied chimney sweep.
Fire burns too fast Extremely dry or soft wood Mix in hardwood.
Mix in less seasoned wood after re is established
(refer to wood fuel section).
No glass doors Add glass doors to slow down air ow.
Overdrafting Check for correct vent height; too much vertical
height creates overdrafting.
Check location of vent termination (refer to
chimney assembly section).
Heatilator • EL36/EL42 • 4044-132 • Rev AD• 7/12