Hearth and Home Technologies CD4842IR Indoor Fireplace User Manual


 
Heatilator • Caliber CD Series • 4040-263 Rev N • 11/08 33
F. Install Vertical Termination Baf e
Remove the glass (refer to Section 14.J.) to access the
rebox and 5 in. inner ue.
Fold the baf e (Figure 7.17) to an approximate 90°
angle (see Figure 7.18).
Squeeze the open end of the bent baf e with one
hand. Insert the baf e bent side up into the inner ue
so that the bottom of the baf e is above the bead on
the inside of the collar. See Figure 7.19.
Release pressure on the baf e so that it is wedged
against the sides of the ue collar. See Figure 7.20.
Replace the glass (refer to Section 14.J.).
Start the appliance.
Note: For vertically terminated installations only.
Figure 7.17 Flat Baf e
Figure 7.18 Baf e Bent to 90° Angle
Figure 7.19 Placing the Baf e
Figure 7.20 Baf e in Place
Note: If installing a vertical vent/termination run off the
top or rear of the appliance, the vertical termination baf e
supplied with the appliance may be used.