Hearth and Home Technologies CD4842IR Indoor Fireplace User Manual


 
Heatilator • Caliber CD Series • 4040-263 Rev N • 11/0812
J. Lighting Instructions (Standing Pilot)
For normal use, activate/deactivate your replace with the wall switch or remote control.
• If your replace must be deactivated for service or an extended period of time, follow the instructions below.
A. This appliance has a pilot which must be lighted by hand. When
lighting the pilot, follow these instructions exactly.
B. BEFORE LIGHTING smell all around the appliance area for gas.
Be sure to smell next to the floor because some gas is heavier
than air and will settle on the floor.
WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electric switch; do not use any phone in your
building.
• Immediately call your gas supplier from a neighbor's phone.
Follow the gas supplier's instructions.
• If you cannot reach your gas supplier, call the fire department.
LIGHTING INSTRUCTIONS
1. Turn wall switch to the "OFF" position or thermostat to the
lowest setting.
2. Remove control access panel.
3. Turn manual gas valve to CLOSED. Wait five [5] minutes to
clear out any gas. If you then smell gas, STOP! Follow "B" in the
safety information above on this label. If you don't smell gas, go
to next step.
4. Turn gas line to "OPEN".
5. Turn pilot knob clockwise to "OFF". (Knob may have to be
depressed to pass "PILOT" position.)
6. Locate pilot assembly inside appliance.
7. Locate red ignitor button.
8. Turn pilot knob to "PILOT" and push in.
9. Continue to hold in pilot knob and push the red ignitor button
12-15 times until small blue pilot flame appears.
10. Continue to hold in pilot knob for approximately one minute. Pilot
should remain lit. If pilot goes out, wait 5 minutes and repeat
Steps 3-9.
11. Release and turn knob counterclockwise to "ON".
12. If appliance will not operate, follow the instructions "TO TURN
OFF GAS TO APPLIANCE" and call your service technician or
gas supplier.
NOTE: To light main burner, turn wall switch to "ON". Do not light by
hand.
TO TURN OFF GAS TO APPLIANCE
1. Turn off wall switch or set thermostat to lowest setting.
2. Remove control access panel.
3. Turn manual gas valve to "CLOSED position. Do not force.
4. Replace control access panel.
Due to high surface termperatures, keep children, clothing and furniture away.
Keep burner and control compartment clean. See installation and operating instructions accompanying the appliance.
WARNING: If you do not follow these instructions exactly, a fire or
explosion may result causing property damage, personal
injury or loss of life.
FOR YOUR SAFETY READ BEFORE LIGHTING
29097D
This appliance needs fresh air for safe operation
and must be installed so there are provisions for
adequate combustion and ventilation air.
This appliance must be installed in accordance with
local codes, if any; if not, follow ANSI Z223.1 or, in
Canada, current CAN/CGA-B149.
WARNING:
Improper installation,
adjustment, alteration, service or maintenance can
cause injury or property damage. Refer to the owner's
information manual provided with the appliance. For
assistance or additional information consult a
qualified installer, service agency or the gas supplier.
CAUTION:
Hot while in operation. Do
not touch. Keep children, clothing, furniture,
gasoline and other liquids having flammable vapors
away.
WARNING RISK OF FIRE
This appliance is intended to burn a specified gas
fuel only. Do not attempt to use with solid wood fuel
or another type of fuel. Do not attempt to modify or
use any other type of gas burner system.
* Also certified for installation in a bedroom or a
bed-sitting room.
* For U.S. only!
C. Use only your hand to push in or turn knob. Never use tools. If
the manual gas valve will not push in or turn by hand, don't try
to repair it; call a qualified service technician. Force or
attempted repair may result in a fire or explosion.
D. Do not use this appliance if any part has been under water.
Immediately call a qualified service technician to inspect the
appliance and to replace any part of the control system and any
gas control which has been under water.
Stop! Read the safety information above on this label.
ON
OFF
PILOT
OFF
PILOT
ON
OFF
PIL
OT
5
ON
OFF
VENT
ON
7
5
8
11
3. CLOSED
4. OPEN
WARNING:
Disconnect the electric power
before servicing. If for any reason the original wire
supplied with the appliance must be replaced, it must be
replaced with 105° C or its equivalent.
For use with natural gas or propane. A conversion
kit as supplied by the manufacturer shall be used to
convert this appliance to the alternative fuel.
This appliance must be properly connected to a
venting system in accordance with the
manufacturer's installation instructions.
NATURAL GAS