Hearth and Home Technologies CD4842IR Indoor Fireplace User Manual


 
Heatilator • Caliber CD Series • 4040-263 Rev N • 11/0810
Clear space 3 ft (914 mm)
in front of appliance
D. Clear Space
WARNING! DO NOT place combustible objects in front of
the replace or block louvers. High temperatures may start
a re. See Figure 2.2.
Avoid placing candles and other heat-sensitive objects on
mantel or hearth. Heat may damage these objects.
Figure 2.2 Clear Space
C. Fan Kit (optional)
If desired, a fan kit may be added. Contact your dealer to
order the correct fan kit.
F. Fixed Glass Assembly
See Section 14.K.
E. Decorative Doors and Fronts
WARNING! Risk of Fire! Install ONLY doors or fronts
approved by Hearth & Home Technologies. Unapproved
doors or fronts may cause replace to overheat.
This replace has been supplied with an integral barrier to
prevent direct contact with the xed glass panel. DO NOT
operate the replace with the barrier removed.
Contact your dealer or Hearth & Home Technologies if the
barrier is not present or help is needed to properly install
one.
For more information refer to the instructions supplied
with your decorative door or front.
G. Remote Controls, Wall Controls and Wall
Switches
Follow the instructions supplied with the control installed
to operate your replace:
For safety:
Install a switch lock or a wall/remote control with child
protection lockout feature.
Keep remote controls out of reach of children.
See your dealer if you have questions.
H. Before Lighting Fireplace
Before operating this replace for the rst time, have a
quali ed service technician:
Verify all shipping materials have been removed from
inside and/or underneath the rebox.
Review proper placement of logs, rockwool and/or other
decorative materials.
Check the wiring.
Check the air shutter adjustment.
Ensure that there are no gas leaks.
Ensure that the glass is sealed and in the proper position
and that the integral barrier is in place.
WARNING! Risk of Fire or Asphyxiation! DO NOT oper-
ate replace with xed glass assembly removed.
Determine if this replace has a standing pilot or an
Intelli re ignition system. Ask your dealer or open control
access panel, look at gas valve assembly.
A standing pilot ignition will have a red or black ignitor
button (refer to Figure 2.3).
• An Intelli re ignition system will not have a button.
Ignitor Button
Figure 2.3 Ignitor Button