Harman Stove Company DVC-500 Stove User Manual


 
5
INTRODUCTION
This remarkable design by Harman features the
Verti-ow Direct Vent Stoker System.
This unique, high efciency unit uses only
outside air for combustion.
Micro-processor controls provide for an au-
tomatic wide range of heat output from 7,000 to
75,000 BTU .
With a big 93 pound hopper capacity, this unit
can burn on high approximately 16 hours or extend
for over 96 hours on low.
A Room Sensor connected to the micro-proces-
sor automatically adjusts the feed rate to compensate
for changes in temperature.
The ash pan is large enough to hold the ash
from one hopper full of coal at any setting.
The DVC 500 is the most advanced coal
stove ever put into production. However, there
are places where it should not be installed. If the
end of the ue pipe is:
1. Less than 8 feet from an air intake.
2. On the side of the house where a window is
left open for sleeping.
3. Less than 5 feet from a door.
4. Less than 7 feet above and 3 feet away from a
public walkway.
5. Less than 3 feet above ground level.
6. Between two buildings less than 10 feet apart.
It is recommended that the end of the ue
pipe terminates at least 12 inches away from the
side of the building in order to minimize any y
ash build-up.
Mobile home installations should be done in
accordance with the Manufactured Home and
Safety Standard (HUD), CFR 3280, Part 24.
DAMP COAL SHOULD NOT BE
LEFT IN THE HOPPER OF A COLD
STOVE.