Harman Stove Company DVC-500 Stove User Manual


 
26
Control and Safety Sensors
ESP
The ESP (Exhaust Sensing Probe) is a temperature
sensing probe located in the exhaust outlet. The ESP
works with the Control to perform all burn rate func-
tions as well as high and low limit control.
Room Sensor
The Room Sensor is a small temperature sensor placed
where you would normally put a thermostat. The
Room Sensor is extended to the stove with normal
thermostat wire. The Room Sensor works with the
ESP and the Control to provide the right size re.
FSS
The FSS (Firebox Static Sensor) is an electronic
pressure sensor reading the rebox pressure. The
FSS works with the ESP Control to adjust the draft
blower speed to compensate for wind and changing
house pressures.
TCP
The TCP (Temperature Control Probe) is located
on the left side of the feeder. The TCP works with
the Control to reduce the feeder temperature if the
temperature begins to rise.
ESP
TCP
This sensor is located in the control box behind
the control board. It is preset and is non-adjust-
able.
FIREBOX STATIC
FSS 1-10-163
TCP
Stove
X
1-10-163
SENSOR