Harman Stove Company XL Indoor Fireplace User Manual


 
The installation of the ShadowLight XL Fireplace Insert
must conform with local codes, or in the absence of local
codes, with National Fuel Gas Code, ANSI Z233.1 (NFPA
54). Installer l'appareil selon les codes ou règlements
locaux, ou, en l'absence de tels règlements, selon les
Codes d'installation CAN/CGA-B149.
The ShadowLight XL Fireplace Insert may be installed
in mobile homes.
CAUTION: This appliance must be vented to the
outside.
Installation and repair of the ShadowLight XL Fireplace
Insert should be done by a qualified service person.
The appliance should be inspected before use and
at least annually by a qualified service person. More
frequent cleaning may be required due to excessive lint
from carpeting, bedding material, etc. It is imperative
that control compartments, burners, and circulating air
passageways of the appliance be kept clean. Any safety
screen or guard removed for servicing an appliance must
be replaced prior to operating the appliance.
S'ASSURER QUE LE BRÛLEUR ET LE COMPARTIMENT
DES COMMANDES SONT PROPRES. VOIR LES
INSTRUCTIONS D'INSTALLATION ET D'UTILISATION
QUI ACCOMPAGNENT L'APPAREIL.
When operating your Harman ShadowLight XL Fireplace
Insert, respect basic safety standards.
Read these instructions carefully before you attempt
to operate the heater. Failure to do so may result in
damage to property or personal injury and may void the
product warranty.
Consult with your local building code agency and insurance
representative before you begin your installation to
ensure compliance with local codes, including the need
for permits and follow-up inspections.
Observing required clearances to combustible materials,
proper connection to an approved venting system, and
the accessibility of the gas and electrical supply must
all be considered when planning the installation of a
ShadowLight XL Fireplace Insert.
Install the ShadowLight XL Fireplace Insert only in
a listed solid-fuel burning factory-built fireplace or
a masonry solid-fuel burning fireplace. The Fireplace
Insert and vent should be enclosed when installed in,
or when passing through, a living area where children
may come in contact with it.Z21.88-2002-CSA 2.33-
2002,CAN/CGA2.17.
Introduction
• Not for use with solid fuel. Not for use with air filters. Ne doit pas etre
utilise avec un combustible solide.
• Also for use in mobile (manufactured) homes after home is sited.
• Tested to ANSI Z21.88-2002 / CSA2.33-2002 / CAN-CGA-2.17-M91
• For use with natural gas or propane. A conversion kit, as supplied by the
manufacturer, shall be used to convert this room heater to the alternate
fuel. Pour utilisation, avec le gaz naturel et le propane. Une trousse de
conversion fournie par le fabricant doit etre utilisee pour passer d’un
combustible a l’autre.
• Keep burner and control compartment clean. See installation and
operating instructions accompanying appliance. S’assurer que le bruleur
et le compartiment des commandes sont propres. Voir les instructions
d’installation et d’utilisation qui accompagnent l’appareil.
During repairs or maintenance of this unit, all sealing gaskets or high
temperature silicone seals on the heat exchanger module must be in-
spected for damage and replaced, if necessary, to prevent any leakage
of exhaust into the living areas.
Electrical Rating: 115 VAC, 60 Hz, < 1.15 AMP
MANTEL CLEARANCE: Combustible mantle up to 8” in depth must be
at least 43” above unit base.
CAUTION: Do not operate the appliance with glass removed, cracked
or broken. Replacement of panel(s) should be done by a licensed or
qualified service person.
CAUTIONNER: N’orére l’appareil avec le verre enlevé, craque ou casse.
Le remplacement du panneau(s) devrait être fait par une personne de
service qualifie ou autorise.
Manufactured by Harman Stove Company
352 Mountain House Road, Halifax, PA 17032
20 Airport Road, West Lebanon, NH 03784
A LABEL (LOCATED NEAR THE BURNER SYSTEM MOD-
ULE) STATES THE FUEL FOR WHICH THE HEATER IS
EQUIPPED.
SAFETY LABEL
WHI #
This appliance is only for use with the type of gas indicated on the rat-
ing plate and may be installed in an aftermarket, permanently located,
manufactured (mobile) home where not prohibited by local codes. See
owner’s manual for details. This appliance is not convertible for use
with other gases, unless a certified kit is used.
• Homologue Pour Le Canada
• Do not remove this label.
RATINGS
Input Rating(Btu/hr)(0-2000 ft)(0-610m)
Input Rating(Btu/hr)(2000-4500ft)(610-1375m)
Min. Input Rating(Btu/hr)
Orifices (DMS)(0-2000 ft)(0-610m)
Orifices (DMS)(2000-4500ft)(610-1375m)
Manifold Pressure (in w.c./kPa)
Min. Manifold Pressure (in w.c./kPa)
Min. Inlet Pressure (in w.c./kPa)
NATURAL
35,000
34,000
21,600
31
33
3.5/.87
1.3/.32
5.0/1.24
PROPANE
35,000
34,500
20,900
50
51
2.5
3.6/.9
11.0/2.75
CAUTION: Hot while in operation. Do not touch. Severe burns may
result. Keep children, clothing, furniture, gasoline and other liquids
having flammable vapors away.
ATTENTION: Les surfaces sont chaudes en service. Ne touchez pas.
Risque de brulure grave. Tenez les enfants, les vatements, le mobilier,
l’essence et autres liquides produisant des vapeurs inflammables B
distance.
Listed Direct Vent Gas Fireplace Heater
Radiateur Ventile
Model: ShadowLight XL Gas Fireplace Insert
4