Specifications
Door Latches
Remove door by pulling latches out as shown and
pulling the bottom of the door out from the unit about
3”. Then lift the door slightly up and off the hooks.
Door Hooks
1
Remove air plate by lifting it up about 3 inches and
then out of firebox. Be careful not to damage side
brick panels
Converting to High Altitude
2
3
4
Remove log. Next, remove screw, washer and
spacer from the center of the rear brick panel. Using
one hand, gently push the side brick/relief door open
slightly and using the other pull the top of the rear
brick panel forward and remove it.
Remove the screws mounting the intake air deflector and lift
it from the firebox. Next locate the screw holding the burner
tube to the firebox floor and remove it. Now the burner
orifice can be removed using a 1/2” deep well socket and
replaced with orifice required for type of fuel being used.
Refer to safety label for orifice size.
If this is a new unit, the Natural Gas Conversion Kit must be
used when installing the Natural Gas High Altitude Kit.