Harman Stove Company XL Indoor Fireplace User Manual


 
Installation
Only For Qualified Installers
Remove three screws to change knob assembly. Install NG knob assembly in place of the LP assembly. Be
sure screws are tight.
5
Place conversion sticker (provided in Kit) on the valve. This
is to permanently mark the valve that it has been converted
to Natural Gas. This label is important in the event that
the valve is ever removed and mixed in with other valves.
Reassemble all components removed during the conversion
process.
6
Mark the proper box on the fuel label with a
permanent marker. Note: If no conversion is
made, the box for propane must still be marked.
7
Safety Label
Use soap and water and/or a gas detector to
check for leaks before lighting the pilot.
8
When installation has been completed, verify the gas inlet
and manifold pressures are within specifications. The safety
label, located inside the bottom of the unit, will have the
information needed to verify correct operation. To read
the safety label, pull the label out away from the unit. Be
sure to use the information for the type of gas that it will
be using.
You must check the unit for any gas leaks using soapy
water or an electronic style leak detector.
16