18INSTALLATION (Options)
Only For Qualified Installers
Connecting the Optional Thermostat
If the optional thermostat is used, it must be
plugged into the TH terminals located on the
valve.
When installing a millivolt control system, use
only a special low resistance thermostat. DO NOT
USE A REGULAR HEATING THERMOSTAT.
Be sure that all electrical connections are clean,
free from corrosion, and tight. Inspect connections
periodically to confirm that no corrosion has built
up over time.
When properly installed and maintained, a mil-
livolt control system should give many years of
trouble-free service.
It is important to use wire of a gauge proper
for the length of the wire:
RECOMMENDED WIRE GAUGES
Maximu m Wire
Length Gauge
100' 14
60' 16
40' 18
25' 20
15' 22
Thermostat
Remote Control Kit
The button on the remote control can be used
to turn the fire on and off.
This remote uses the ultrasonic control method
and does not need to be pointed directly at the fire-
place.
The kit includes installation instructions, a hand
held sending unit, receiving unit, mounting bracket,
and all wiring.
Note: The ON/OFF switch must be “OFF”
when using the remote. If the switch is in the “ON”
position, the fire will stay on even when the set tem-
perature on the thermostat is reached.
Glass Grill
To install the glass grill remove the door and
slide the top of the vertical bars up into the slots at
the top of the firebox opening. Lower the grill down
so the bottom of the vertical bars rest just inside the
lip at the bottom of the firebox opening.
Reinstall door.
Burner Button
Glass Grill
Evaluation notes were added to the output document. To get rid of these notes, please order your copy of ePrint IV now.