Harman Stove Company Conquest Gas Stove Stove User Manual


 
11INSTALLATION
Only For Qualified Installers
Maximum of four 45
0
elbows allowed.
Subtract three feet of total horizontal pipe
length for each of the 3rd and 4th 45
0
elbows
used.
Maximum of two 90
0
elbows allowed.
Subtract five feet of total horizontal pipe
length for second elbow.
Venting with 6
5
/
8
” x 4” Pipe
A combination of one 90
0
elbow and two 45
0
elbows is allowed.
Subtract three feet of total horizontal pipe
length for each 45
0
elbow used.
This appliance must not be
connected to a chimney flue
serving a separate solid fuel
burning appliance.
6
5
/
8
to 8” Increaser
8”
CONQUEST
Rear Vent
A snorkel termination is
recommended when no
vertical pipe is used.
Vent termination must remain within the
shaded area regardless of configuration.
Evaluation notes were added to the output document. To get rid of these notes, please order your copy of ePrint IV now.