Getting Maximum Efficiency From the Appliance
To achieve the maximum benefit and performance
from this appliance, familiarize yourself with this
manual and the appliance.
1. The salt level should always be at least 1/3 full.
Refill the salt when the level drops below the
water level in the brine cabinet. A resin cleaner
can be used on a monthly basis. A clean pellet,
solar, or cube-type salt is recommended. Do
not use rock salt.
Caution: Do not mix different types of salt.
2. You may use a salt substitute (such as
potassium chloride) in place of water
conditioner salt. A Hague dealer should be
contacted before a switch is made to a salt
substitute. If potassium chloride is used in
place of salt, the technician should select the
potassium option during the programming of
the controller. See Service Settings.
Caution: Do not use potassium chloride if there
is iron and/or manganese in the water.
3. Program the appliance to regenerate at a time
when the water is not being used. If there is
more than one appliance, allow two hours
between each regeneration.
4. If dirt, sand, or large particles are present in the
water supply, the appropriate Hague filter can
eliminate this problem. See WaterMax
®
Filter
Specifications.
5. The appliance may be disinfected with 5.25%
sodium hypochlorite, which is the active
ingredient in household chlorine bleach. To
disinfect the appliance, add 4.0 fluid ounces of
chlorine bleach solution to the brine well of the
brine tank. The brine tank should have water in
it. Start a manual regeneration.
6. Protect the appliance, including the drain line,
from freezing.
7. The bypass valve (located on the main control
valve) enables you to bypass the appliance if
any work is being performed on the appliance,
well pump, or plumbing. See Bypass Valve.
Use it also for watering plants or lawns with
untreated water. To bypass, turn the blue
cone-shaped knob counterclockwise until it
stops; turn it clockwise to restore service.
8. Before putting the appliance back in service
after work has been performed, turn on the
nearest cold water tap until water runs clear.
9. Adhere to all operational, maintenance, and
placement requirements.
10. Inspect and clean the brine tank and air
check/draw tube assembly annually or when
sediment is present in the brine tank.
11. Potassium permanganate will need to be added
periodically to any iron filter.
Six-Button Controller
This appliance features a six-button controller with
an LCD display. The controller can be used to view
the appliance’s status, perform regenerations, and
change settings. An independent Hague dealer
should set the Service Settings during installation of
the appliance.
Figure 1: Six-Button Controller
LCD Display
Buttons