WaterMax 60 Series Owner’s Manual 11/10/2008 21
Salt Depths
Based on the water level measured from the bottom of the brine cabinet with grid plate, the following depths
correlate to the amount of salt used per regeneration:
Modes 1 and 3 Mode 2
Salt (lb) Depth (in.) Salt (lb) Depth (in.)
1
1.0 5-3/4 1.0 5
1.6 6 1.6 5-1/4
2.5 7-5/8 2.5 5-7/8
2.7 8 2.7 5-7/8
3.0 8-7/8 3.0 6
4.2 9-5/8 4.2 7-1/4
6.0 11-7/8 6.0 8-7/8
6.2 12 6.2 8-7/8
6.5 12-3/8 6.5 9
8.5 14-3/4 8.5 9-5/8
9.0 15-3/8 9.0 9-7/8
9.3 15-7/8 9.3 10
9.6 16-1/2 9.6 10-3/4
10.7 17-3/8 10.7 11-3/4
14.4 22 14.4 13-5/8
1
These depths reflect 50% of the total brine refill for the Absolute Brining feature.
Note: Bold numbers pertain to available settings listed under Mode 1 and 2 Service Settings.
To maintain peak performance of the appliance, inspect and clean the brine tank and air check/draw tube
assembly annually or when sediment is present in the brine tank.