Assembly and Parts, Cont.
Brine Valve Housing Assembly Cont.
53511 Brine
Piston
The Piston should have an O-Ring on the shaft side of the flange and a spring pressed onto a boss on
the other side. The O-Ring should be free of defects such as cuts or debris on the shaft side.
53510 Housing
Just inside the entrance hole for the Brine Piston (53511) is a concave seat area that must be free of
defects such as nicks, indentations, or debris. This seat area ensures a leak-free seal for the static O-
Ring on the Brine Piston. If any defects are detected by visual inspection, repair or replace as needed.
90843 0.5 gpm
Flow Control
The Flow Button has two distinct and different sides. One is “flat”; the other is “concave.” The button
should be centered in the housing opening with the four locator “ribs” with the concave side facing the
Housing End Cap (93247).
93247 Housing
End Cap
The Cap is held in place by two 3/4" thread cutting screws that engage the Housing flange. An O-Ring
seals the Cap and Housing. Place the O-Ring into the housing opening, lubricate with silicone grease
and then using a twisting action, pressure insert the Cap.
Caution: The 3/8" locking clip (200199) must be installed to prevent air from being drawn into the
appliance during brine rinse.